Tabata USA is recalling about 250 TUSA RS-670 regulators.
The first-stage’s balance chamber plug can loosen from
the regulator, causing a high-pressure leak, creating unstable
pressure and posing a drowning hazard. Undercurrent called
TUSA’s customer service line but the representative couldn’t
tell us how the faulty plug was discovered. However,
on TUSA’s website, it says the company was “recently
informed” about the loosening of the plug, suggesting
TUSA dealers and/or customers discovered the problem.
The recall for the regulators involves the following
serial numbers: UR600022 through UR600029, UR600031
through UR600103, UR6000637 through UR6000676,
UR600708 through UR600716, UR600737 through
UR600776. The serial number and TUSA logo are printed
on the regulators, which were made in Japan and sold in the
U.S. between May and September 2009.
Customers should immediately stop using the regulators
and return the product to TUSA or an authorized dealer
for a free inspection and replacement. For information,
call TUSA at (800) 482-2282 between 8:30 a.m. and 5 p.m.
Pacific, Monday through Friday, or e-mail info@tusa.com.